1. Which Certificate of Fitness is necessary to service portable extinguishers?
A. A Fire Safety Director's C of F.
B. A Deputy Fire Safety Directors C of F.
C. A Special C of F for servicing extinguishers.
D. A Sprinkler and Standpipe C of F.
The following questions presented will test your knowledge of the material, and expose you to the different types of questions you might see when you take your written exams. You will note that the questions below are in various formats, this is simply an exercise to make you a better test taker. To do well on these tests you must know the material, read carefully, ask yourself "what is the question asking?" and read all the answers before you make your selection.
Note: The answer to each question is in a little box like the example below, to view the answer click on the arrow.
2. Extinguisher servicing and maintenance must be performed at least how often?
A. Annually
B. Semi-annually
C. Every two years
D. Every three years
3. The record of Extinguisher maintenance is kept where?
A. On a card attached to the extinguisher
B. On a card in the office of the FSD
C. The owner keeps the record anyway he wants.
D. On record at the Bureau of Fire Prevention
4. What would not be found on the Fire Extinguisher maintenance record?.
A. The name of the person servicing the Extinguisher.
B. Month and year.
C. C of F #
D. Local Fire Department number.
5. How often does the FSD perform a visual inspection of the portable fire extinguishers?
A. Daily
B. Weekly
C. Monthly
D. Semi-annually

New questions added on: August 8, 2007
Extinguishers
6. A class " K " fire extinguisher would most likly be found where in the building?
A. Work room
B. Kitchen
C. Office
D. Lobby
7. The 5th floor of your office building  has 13,000 square feet of floor area and does not have sprinkler protection, at least how many 2-A rated  fire extinguishers are required on that floor?
A. 1
B. 2
C. 3
D. 4
8. On the 2nd floor of your office building, that is fully sprinklered, you have 13,000 square feet of floor area, how many 2-A rated fire extinguishers are required on that flor?
A. 1
B. 2
C. 3
D. 4
9. In a hotel that has 7,000 square feet of floor space on the 4th floor requires at least how many 2-A rated fire extinguishers?
A. 2
B. 4
C. 6
D. 8
10. In either a Class E or Class J-1 building, the maximum travel distance to reach a fire extinguisher can not exceed how many feet?
A. 45
B. 55
C. 65
D. 75
11. What type of extinguisher would not be used on an electrical fire?
A.Carbon dioxide (CO-2)
B. Dry Chemical
C. Water
D. An A,B,C rated extinguisher